product features
â Adopt fully digital voltage and current double closed-loop control, advanced SPWM technology, output pure sine wave.
â it has two output modes of mains power bypass and inverter output, and has the function of uninterrupted power supply.
â 4 charging modes to choose from: solar only, mains priority, solar priority, hybrid charging.
â Advanced MPPT technology with an efficiency of up to 99.9%.
â LCD lcd screen design,3 LED indicators, dynamic display system data and operating status.
â ON/OFF ship type switch controls AC output.
â with power saving mode function, reduce no-load loss.
â intelligent adjustable speed fan is adopted to efficiently dissipate heat and extend system life.
â comes with lithium battery activation function, support lead-acid battery, lithium battery access.
â has a number of protection functions,360 ° all-round protection.
â with complete short circuit protection, over-undervoltage protection, overload protection, back-irrigation protection, etc.
â lithium batteries can be activated in ac and photovoltaics.
technical parameter
model | HF2420S60-100 | HF2430S60-100 |
mains mode | 220/230Vac (170Vac~280Vac) Âą2%ïž(90Vac-280Vac)Âą2% | |
rated input voltage input voltage range | ||
frequency | 50Hz/ 60Hz (Auto Detect) | |
frequency range | 47Âą0.3Hz ~ 55Âą0.3Hz (50Hz)/57Âą0.3Hz ~ 65Âą0.3Hz (60Hz); | |
overload/short circuit protection | breakers | |
efficiency | >95% | |
transition time (bypass and inverter) | 10ms (typical) | |
ac back-irrigation protection | yes | |
maximum side-by-side current | 30A | |
inverter mode | ||
output voltage waveform | pure sine wave | |
RATED OUTPUT POWER (VA) | 2000 | 3000 |
RATED OUTPUT POWER(W) | 2000 | 3000 |
power factor | 1 | |
Rated output voltage (Vac) | 230Vac | |
output voltage error | Âą5% | |
Output Frequency Range (Hz) | 50Hz Âą 0.3Hz/60Hz Âą 0.3Hz | |
efficiency | >92% | |
overload protection | (102% < load <125%) ¹ 10%: error is reported and the output is turned off after 5 minutes; | |
(125% < load <150%) ¹10%: error is reported and output is turned off after 10 seconds; | ||
load > 150% Âą10%: error is reported and the output is turned off after 5 seconds; | ||
peak power | 4000 | 6000 |
with on-load motor capability | 1HP | 2HP |
output short-circuit protection | breakers | |
bypass circuit breaker specifications | 30A | |
rated battery input voltage | 24V (MIN. START-UP VOLTAGE22V) | |
battery voltage range | 20.0Vdc~33Vdc Âą 0.6Vdc (Undervoltage Alarm / Shutdown Voltage / Overvoltage Alarm / Overvoltage Recovery… LCD screen can be set) | |
power-saving mode | LOAD âĪ25W | |
mains charging | ||
battery type | lead-acid or lithium batteries | |
maximum charge current | 60A | 80A |
charge current error | Âą 5Adc | |
charging voltage range | 18.0Vdc~33Vdc | |
short circuit protection | circuit breakers and fuses | |
circuit breaker specifications | 30A | |
overcharge protection | alert and turn off charging after 1 minute | |
solar charging (the following three options to choose to match) | ||
MAXIMUM PV OPEN CIRCUIT VOLTAGE | 100Vdc | |
PV OPERATING VOLTAGE RANGE | 30-100Vdc | |
MPPT VOLTAGE RANGE | 30-95Vdc | |
battery voltage range | 18-33Vdc | |
maximum output power | 1400W | |
solar charging current range (programmable). | 0-60A | |
charging short circuit protection | fuse the fuse | |
wiring protection | reverse polarity protection | |
certified specifications | ||
specification certification | CE(IEC/EN62109-1ã-2)ãROHS2.0 | |
EMC CERTIFICATION LEVEL | EN61000 | |
operating temperature range | -15°C to 55°C | |
storage temperature range | -25°C ~ 60°C | |
humidity range | 5% to 95% (triple paint protection) | |
noises | âĪ60dB | |
cooling | forced air cooling, wind speed adjustable | |
communication interface | USB/RS485 (Bluetooth/WiFi/GPRS)/dry node control | |
SIZE (L*W*D) | 378mm*280mm*103mm | |
WEIGHT (KG) | 6.2 |