product features
â Adopt fully digital voltage and current double closed-loop control, advanced SPWM technology, output pure sine wave.
â it has two output modes of mains power bypass and inverter output, and has the function of uninterrupted power supply.
â 4 charging modes to choose from: solar only, mains priority, solar priority, hybrid charging.
â Advanced MPPT technology with an efficiency of up to 99.9%.
â LCD lcd screen design,3 LED indicators, dynamic display system data and operating status.
â ON/OFF ship type switch controls AC output.
â with power saving mode function, reduce no-load loss.
â intelligent adjustable speed fan is adopted to efficiently dissipate heat and extend system life.
â comes with lithium battery activation function, support lead-acid battery, lithium battery access.
â has a number of protection functions,360 ° all-round protection.
â with complete short circuit protection, over-undervoltage protection, overload protection, back-irrigation protection, etc.
technical parameter
model | ELM4825U60-145 | ELM4830U60-145 | ELM4835U80-145 |
mains mode | |||
rated input voltage | 110/120Vac | ||
input voltage range | (90Vac~140Vac) Âą2% | ||
frequency | 50Hz/ 60Hz (Auto Detect) | ||
frequency range | 47Âą0.3Hz ~ 55Âą0.3Hz (50Hz)/57Âą0.3Hz ~ 65Âą0.3Hz (60Hz); | ||
overload/short circuit protection | breakers | ||
efficiency | >95% | ||
transition time (bypass and inverter) | 10ms (typical) | ||
ac back-irrigation protection | yes | ||
maximum side-by-side current | 40A | ||
inverter mode | |||
output voltage waveform | pure sine wave | ||
RATED OUTPUT POWER (VA) | 2500 | 3000 | 3500 |
RATED OUTPUT POWER (W) POWER FACTOR | 2500 | 3000 | 3500 |
1 | |||
Rated output voltage (Vac) | 120Vac | ||
output voltage error | Âą5% | ||
Output Frequency Range (Hz) | 50Hz Âą 0.3Hz/60Hz Âą 0.3Hz | ||
efficiency | >90% | ||
overload protection | (102% < load <110%) ¹ 10%: error is reported and the output is turned off after 5 minutes; | ||
(110% < load <125%) ¹10%: error is reported and output is turned off after 10 seconds; | |||
load > 125% Âą 10%: error is reported and the output is turned off after 5 seconds; | |||
peak power | 4000VA | 4500VA | 5000VA |
output short-circuit protection with on-load motor capability | 1HP | 2HP | 2HP |
breakers | |||
bypass circuit breaker specifications | 40A | ||
rated battery input voltage | 48V (MIN. START-UP VOLTAGE44V) | ||
battery voltage range | 40.0Vdc~60Vdc Âą 0.6Vdc (Undervoltage Alarm / Shutdown Voltage / Overvoltage Alarm / Overvoltage Recovery… LCD screen can be set) | ||
power-saving mode | LOAD âĪ50W | ||
mains charging | |||
battery type | lead-acid or lithium batteries | ||
maximum charge current | 40A | ||
charge current error | Âą 5Adc | ||
charging voltage range | 40 â60Vdc | ||
short circuit protection | circuit breakers and fuses | ||
circuit breaker specifications | 40A | ||
overcharge protection | alert and turn off charging after 1 minute | ||
solar charging | |||
MAXIMUM PV OPEN CIRCUIT VOLTAGE | 145Vdc | ||
PV OPERATING VOLTAGE RANGE | 60-145Vdc | ||
MPPT VOLTAGE RANGE | 60-115Vdc | ||
battery voltage range | 40-60Vdc | ||
maximum output power | 3200W | 4200W | |
solar charging current range (programmable) | 0-60A | 0-80A | |
charging short circuit protection | fuse the fuse | ||
wiring protection | reverse polarity protection | ||
certified specifications | |||
specification certification | CE(IEC/EN62109-1ã-2)ãROHS2.0 | ||
EMC CERTIFICATION LEVEL | EN61000 | ||
operating temperature range | -15°C to 55°C | ||
storage temperature range | -25°C ~ 60°C | ||
humidity range | 5% to 95% (triple paint protection) | ||
noises | âĪ60dB | ||
cooling | forced air cooling, wind speed adjustable | ||
communication interface | USB/RS485 (Bluetooth/WiFi/GPRS)/dry node control | ||
SIZE (L*W*D) | 430mm*338mm*126mm | ||
WEIGHT (KG) | 10 |